Permanent Magnet DC Motors
dcmotors

 

 

These fractional HP permanent magnet DC Motors use permanent (magnetic) field excitation.

 

Range:

  • Torque: 1 KGCM up to 60 KGCM
  • Speed: 1000 up to 5000 rpm
  • Input Power: Up to 1000 W
  • Voltages: 12V to 220 V DC

Standard Features :

  • Stromtium Ferrite magnets used
  • Totally Enclosed type construction
  • Prelubricated sealed imported bearings on both the ends of shaft
  • Dynamically balanced Rotors
  • Compact and light weight
  • Steel body protected against corrosion.
  • F- Class insulation standard
  • Connection through flying Leads/Terminal Box

 

Products Range

ce CE
QC Policy

 

Standard Options (EXTRA) :

  • Stromtium Ferrite magnets used
  • Totally Enclosed type construction
  • Prelubricated sealed imported bearings on both the ends of shaft
  • Dynamically balanced Rotors
  • Compact and light weight
  • Steel body protected against corrosion.
  • F- Class insulation standard
  • Connection through flying Leads/Terminal Box
Rating Chart :
Model
Wattage(W)
Speed (rpm)
Voltage (V DC)
Torque (KGCM)
Body Dia
From
To
From
To
From
To
From
To
60
20
75
1000
5000
12
90
upto
1
85
40
400
1000
5000
24
230
2
10
110
60
800
1000
3000
24
230
12
25
118
180
1200
1000
3000
24
230
35
45
We also offer Geared PMDC Motors

SELECTION OF MOTOR :

PMDC motor is a constant Torque motor it gives constant torque staring from standstill to rated speed. It is used for variable speed requirements in industrial applications.

Due to easy availability of cost effective good quality powerful magnets these motors are replacing conventional separately wound motors. They offer a very cost effective solution for low power variable speed applications.

We need following parameters to offer a suitable motor to customer:
1. Power (Watts / HP); alternatively
2.Torque (Kgcm or Nm)
3.Speed (rpm)
4.Supply Voltage. (VDC)
5.Mounting (Flange / Foot / Face / Special)

Using above information, with some simple arithmetic we can find the Torque (or power) of the motor and ultimately our model of the motor from enclosed datasheets.

Power (W) = Torque (Kg-cm) X Speed (rpm)
                    -----------------------------------
                                        100
OR

                  Torque (Kgcm) = 100 X Power (W)
                   ---------------------------------------
                                Speed (rpm)

In case of Geared Motors, to select a correct Gearbox, the Ratio of the GB and the Torque required at the O/P of the GB shaft is needed.

Ratio: N1 – Speed of the Motor
         ----------------------------
         N2 – Output Speed

For Geared Motors,

Output Torque = Input Torque X Gear Box Ratio. (Output Torque of motor)

Output Speed = Input (Motor) Speed / Gear Box Ratio.

Required Conversion charts

Torque: (Rounded figures for convenience)

1 Kg-M = 10 Nm = 100 Kg-Cm
1 Kg-Cm = 0.88 lb-inch

Power:
1 HP = 756 Watts.
1KW = 1000 Watts.

We can offer following type of gearboxes:
1.Worm (Output right angled): Ratios available from min.10: 1 to max. 70:1.
2.Helical gearboxes (inline shaft) with ratios 5.3,10,15,19,24:1.
3.Planetory gearboxes (inline shaft) with ratios 3:1 to 1200:1
4.Spur gearboxes (inline shaft) with ratios 50:1 to 1500:1

MOTOR SPECIFICATIONS & DATASHEETS :
1. 110 DIA. MOTOR DATASHEET

> 1500 RPM MOTORS
HP/Watt
Model
IEC Frame
Volt
Amp
Torque
(KgCm)
Mtg.
Type
Wt.(Kg)
B5
B14
V1
V2
I1
I2
0.25 / 180
TM110
71 B5
71 B14
180
220
1,3
1,2
13
Foot/ Flg
TEFC
7,8
0.5 / 370
QM110
71B5
71 B14
180
220
2,5
2,0
25
Foot/ Flg.
TEFC
9,0
0.75/ 563
HM 110
80 B5
80 B 14
180
220
3,8
3,2
38
Foot/ Flg.
TEFC
13,1
1.0 / 750
HM110
80 B5
80 B14
180
220
4,5
4,0
50
Foot/ Flg.
TEFC
13,1

> 3000 RPM MOTORS
HP/Watt
Model
IEC Frame
Volt
Amp
Torque
(KgCm)
Mtg.
Type
Wt.(Kg)
B5
B14
V1
V2
I1
I2
0.5 / 370
TM110
71 B5
71 B14
180
220
2,8
2,2
13
Foot/ Flg
TEFC
7,8
1.0 / 750
QM110
71B5
71 B14
180
220
5,0
4,5
25
Foot/ Flg.
TEFC
9,0
1.5/ 1125
HM 110
80 B5
80 B 14
180
220
8,0
6,8
38
Foot/ Flg.
TEFC
13,1
2.0 / 1500
HM110
80 B5
80 B14
180
220
11,0
10,0
50
Foot/ Flg.
TEFC
13,1

INS.CLASS.’F’, COLOUR: BLACK, TERMINAL BOX STD., DUTY: S1
FOOT MOUNTING NOT DIMENSIONALLY MATCHING AS PER IEC FRAME.

2. MOTOR DIA.110: GEARED (ELGB WORM)
ELGB WORM (Right angled) GB: Rated Torque 250Kg-Cm
Ref.Drg.No.956
Foot mounting type.
Ratios: 12,18,24,36,48,55,60:1               Supply voltage: 24,36,48,180,220 VDC

HP /
Watt
Motor
Model
Motor Speed
(rpm)
Geared Speed (rpm)
Torque (Kg-Cm)
Wt.(Kg)
     
N1
N2
N3
N4 N5 N6
N7
T1 T2 T3
T4
T5
T6
T7
 
0.25 / 180
TM110
1500
12
0
80
60
40 30 25
20
15
0
225 300
450
600
*720
*900
10
2
0.5/
375
QM
110
1500
12
0
80
60
40 30 25
20
30
0
450 600
*900
*125
0
*1500
*1800
11
5
0.5 / 375 TM
110
3000 25
0
16
0
12
0
80 60 50 40 15
0
220 300 450 *600 *750
*900
10
2
1.0 / 750 QM
110
3000 25
0
16
0
12
0
80 60 50 40 30
0
150 600 900 125
0
1500
1800
11
5

* Selection subject to consideration of application.
INS.CLASS.’F’, COLOUR: BLACK, TERMINAL BOX STD., DUTY: S1
FOOT MOUNTING NOT DIMENSIONALLY MATCHING AS PER IEC FRAME.
GEARBOX ORIENTATION AS PER ABOVE DRG.
CHANGE REQUIRED, TO BE SPECIFIED FROM DRG.1636

3. 85 DIA. MOTOR DATASHEET

> 1500 RPM MOTORS
HP / Watt
Model
Model
Amp
L(mm)
Torque
(Kg-Cm)
Mounting
Type
Wt.(Kg)
V1
V2
I1
I2
0.04/30
SM85
180
220
0,4
0,4
165
2
Foot/Flg.
TEFC
2,4
0.08/60
DM85
180
220
0,6
0,6
193
4
Foot/Flg.
TEFC
3,3
0.10/75
TM85
180
220
0,8
0,7
221
5
Foot/Flg.
TEFC
4,5
0.16/120
QM85
180
220
1,0
1,0
249
8
Foot/Flg.
TEFC
4,7
* Selection subject to consideration of application.
960 RPM / 6 pole motor can be offered in AA . Subject to confirmation from factory.

> 3000 RPM MOTORS
HP / Watt
Model
Model
Amp
L(mm)
Torque(Kg-Cm)
Mounting
Type
Wt.(Kg)
V1
V2
I1
I2
0.08/60
SM85
180
220
0,4
0,4
165
2
Foot/Flg.
TEFC
2,4
0.16/120
DM85
180
220
0,6
0,6
193
4
Foot/Flg.
TEFC
3,3
0.2/150
TM85
180
220
0,8
0,7
221
5
Foot/Flg.
TEFC
4,5
0.3/240
QM85
180
220
1,0
1,0
249
8
Foot/Flg.
TEFC
4,7

4. MOTOR 85 DIA.: LOW VOLTAGE MOTORS

> 1500 RPM MOTORS
HP / Watt
Model
Model
Amp
L(mm)
Torque(Kg-Cm)
Mounting
Wt.(Kg)
V1
V2
V3
I1
I2
I3
0.04/30
SM85
24
36
48
1,7
1,2
1,0
165
2
Foot/Flg.
2,4
0.08/60
DM85
24
36
48
3,5
2,5
1,7
193
4
Foot/Flg.
3,3
0.10/75
TM85
24
36
48
4,0
3,0
2,2
221
5
Foot/Flg.
4,5
0.16/120
QM85
24
36
48
7
4,6
3,6
249
8
Foot/Flg.
4,7

> 3000 RPM MOTORS
HP / Watt
Model
Model
Amp
L(mm)
Torque(Kg-Cm)
Mounting
Wt.(Kg)
V1
V2
V3
I1
I2
I3
0.08/60
SM85
24
36
48
3,7
2,7
1,9
165
2
Foot/Flg.
2,4
0.16/120
DM85
24
36
48
4,2
3,2
2,4
193
4
Foot/Flg.
3,3
0.2/150
TM85
24
36
48
7,2
4,8
3,8
221
5
Foot/Flg.
4,5
0.3/240
QM85
24
36
48
13,0
9,2
6,8
249
8
Foot/Flg.
4,7
INS.CLASS.’F’, COLOUR: BLACK, DUTY: S1, TEFC TYPE
FOOT / FLANGE AND FACE MOUNTING AS PER TC DRAWINGS. (NOT MATCHING IEC FRAME). SUPPLY THRU FLYING LEADS.

5. MOTOR DIA.85: GEARED (TCGB IL)
TCGB HELICAL (Inline) GB: Rated Torque 80Kg-Cm: Ref.Drg.No.1650
Flange mounting type.
Ratios: 5.3,10,15,19,24:1           Supply voltage: 24,36,48,180,220 VDC

HP /
Watt
Motor
Model
Motor Speed
(rpm)
Geared Speed (rpm)
Torque (Kg-Cm)
Wt.(Kg)
     
N1
N2
N3
N4
N5
T1
T2
T3
T4
T5
 
0.04/30
SM85
1500
280
150
100
75
60
10
20
30
40
50
3,4
0.08/60
DM85
1500
280
150
100
75
60
20
40
60
80
100
4,3
0.10/75
TM 85
1500
280
150
100
75
60
25
50
75
100
*125
5,4
0.08/60
SM85
3000
550
300
200
150
120
10
20
30
40
50
3,4
0.16/120
DM85
3000
550
300
200
150
120
20
40
60
80
*100
4,3
0.2/150
TM85
3000
550
300
200
150
120
25
50
75
100
*125
5,4
* Selection subject to consideration of application.

INS.CLASS.’F’, COLOUR: BLACK, DUTY: S1, TEFC TYPE
FOOT / FLANGE AND FACE MOUNTING AS PER TC DRAWINGS. (NOT MATCHING IEC FRAME). SUPPLY THRU FLYING LEADS.

6. MOTOR DIA.85: GEARED (TCGB WORM)
TCGB WORM (Right angled) GB: Rated Torque 150Kg-Cm
Ref.Drg.No.2248 / 2247
Flange / Foot mounting type.
Ratios: 10,16,24,48:1                  Supply voltage: 24,36,48,180,220 VDC

HP / Watt
Motor Model
Motor Speed (rpm)
Geared Speed (rpm)
Torque (Kg-Cm)
Wt.(Kg)
N1
N2
N4
N4
T1
T2
T3
T4
0.04/30
SM85
1500
150
90
60
30
20
30
50
100
3,4
0.08/60
DM85
1500
150
90
60
30
40
60
100
*200
4,3
0.10/75
TM85
1500
150
90
60
30
50
80
125
*250
5,4
0.16/120
QM85
1500
150
90
60
30
80
120
*200
*400
5,7
0.08/60
SM85
3000
300
180
120
60
20
30
50
100
3,4
0.16/120
DM85
3000
300
180
120
60
40
60
100
*200
4,3
0.2/150
TM85
3000
300
180
120
60
50
80
125
*250
5,4
0.3/240
QM85
3000
300
180
120
60
80
120
*200
*400
5,7
* Selection subject to consideration of application.

INS.CLASS.’F’, COLOUR: BLACK, DUTY: S1, TEFC TYPE
FOOT / FLANGE AND FACE MOUNTING AS PER TC DRAWINGS. (NOT MATCHING IEC FRAME). SUPPLY THRU FLYING LEADS.
GEARBOX ORIENTATION AS PER ABOVE DRG.
CHANGE REQUIRED, TO BE SPECIFIED FROM DRG.1636

7. 60 DIA. MOTOR DATASHEET

> 1500 RPM MOTORS
HP / Watt
Model
Voltage(Vdc)
Current(Amp)
Lmm
Torque
(Kg-Cm)
Mtg.
Weight
(Kgs)
V1
V2
V3
V4
I1
I2
I3
I4
0.02/15
SM60
12
24
36
48
1,8
1,0
1,0
0,8
140
1
Flange
1,1
0.03/25
DM60
12
24
36
48
3,0
1,8
1,0
0,8
178
2
Flange
1,5

> 3000 RPM MOTORS
HP / Watt
Model
Voltage(Vdc)
Current(Amp)
Lmm
Torque
(Kg-Cm)
Mtg.
Weight
(Kgs)
V1
V2
V3
V4
I1
I2
I3
I4
0.04/30
SM60
12
24
36
48
2,0
1,2
1,2
1,0
140
1
Flange
1,1
0.03/25
DM60
12
24
36
48
3,2
2,0
1,2
1,0
178
2
Flange
1,5
INS.CLASS.’F’, COLOUR: BLACK, DUTY: S1, TEFC TYPE
FOOT / FLANGE AND FACE MOUNTING AS PER TC DRAWINGS. (NOT MATCHING IEC FRAME). SUPPLY THRU FLYING LEADS.

8. MOTOR DIA.60: GEARED (TCGB WORM NM)
TCGB WORM (NM) GB: Rated Torque 50Kg-Cm: Ref.Drg.No.2332
Flange mounting type.
Ratios: 12,16,24,48:1              Supply voltage: 12,24,36,48 VDC

HP / Watt
Motor Model
Motor Speed (rpm)
Geared Speed (rpm)
Torque (Kg-Cm)
Wt.(Kg)
N1
N2
N4
N4
T1
T2
T3
T4
0.02/15
SM60
1500
120
90
60
30
10
17
25
50
1,8
0.03/25
DM60
1500
120
90
60
30
20
28
42
*83
2,1
0.04/30
SM60
3000
240
180
125
60
10
17
25
50
1,8
0.03/50
DM60
3000
240
180
125
60
20
28
42
*83
2,1
*Selection subject to consideration of application.

9. MOTOR DIA.60: GEARED (TCGB IL)
TCGB HELICAL (Inline) GB: Rated Torque 80Kg-Cm: Ref.Drg.No.2008
Flange mounting type.
Ratios: 5.3,10,15,19,24:1               Supply voltage: 12,24,36,48 VDC

HP /
Watt
Motor
Model
Motor Speed
(rpm)
Geared Speed (rpm)
Torque (Kg-Cm)
Wt.(Kg)
     
N1
N2
N3
N4 N5 T1 T2 T3
T4
T5
 
0.02/15
SM60
1500
280
150
100
75
60
5
10
15
20
25
1,5
0.03/25
DM60
1500
280
150
100
75
60
9
17
25
33
40
2,0
0.04/30
SM60
3000
550
300
200
150
120
5
10
15
20
25
1,5
0.06/50
DM60
3000
550
300
200
150
120
9
17
15
20
25
2,0

*Selection subject to consideration of application.
INS.CLASS.’F’, COLOUR: BLACK, DUTY: S1, TEFC TYPE
FOOT / FLANGE AND FACE MOUNTING AS PER TC DRAWINGS. (NOT MATCHING IEC FRAME). SUPPLY THRU FLYING LEADS.
GEARBOX ORIENTATION AS PER ABOVE DRG.
CHANGE REQUIRED, TO BE SPECIFIED FROM DRG.1636

 